Descarga la aplicación para disfrutar aún más
Vista previa del material en texto
Herramientas Experimentales de la Física de Superficies (para estudiar sistemas bidimensionales y superficies en general) Oscar Grizzi Advanced Anti-rust Chromium Plate on Terracotta Army Weapons 2200 years ago? Gold-Plated Silver Dish - Sasavid Period - Azerbaijan Museum - Tabriz - Iranian Azerbaijan – Iran. How artisans centuries ago achieved sophisticated gilding, such as on the St. Ambrogio golden altar from 825 AD, is now coming to light. ( American Chemical Society ) Importancia de las superficies en la antigüedad Las superficies reales: • Son complejas y están mal definidas: formadas por policristales, desordenadas, con defectos, bordes de granos • Muy dependientes de la interface (gas, sólido, líquido) • Efectos de segregación • Se rompe la simetría que existe en el interior, de 3D a 2D: nuevas estructuras cristalográficas y estados electrónicos Y además hay poco material, 1015 / cm2 vs 1021 / cm3 Difícil hacer experimentos reproducibles! Propuesta de la Física de Superficies: estudiar superficies monocristalinas de bajo índice, entender estas superficies ideales primero, introducir gradualmente defectos, cambios, otros elementos y esperar que estos modelos tengan alguna semejanza con los casos reales Preguntas: • Composición: qué átomos, moléculas hay?, cuantificar • Donde están ubicados: Topografía, estructura cristalina, sitios de adsorción, defectos • Cómo se mueven: vibraciones, segregación, difusión • Estructura electrónica: nuevos estados, bandas, gaps, función trabajo • Como responde la superficie: dependencia con temperatura, Excitación con luz, rayos-X, electrones, iones, campos… Herramientas pare responder las preguntas Átomos neutros Iones Fotones Campos Calor Electrones • Microscopía (STM – AFM – MFM, SEM, TEM, FIM): imagen directa, incluye defectos. Información Local, difusión. ¿Representa a toda la superficie? • Difracción (LEED, GIXD, LEAD): LEED es simple y rápida. Alta precisión. LEAD produce poco daño en películas orgánicas y es sensible a la última capa atómica. • Espectroscopía (XPS, UPS, IR, AES, HREELS, otras basadas en luz de sincrotrón, RBS, ISS, SIMS, PIXE…): composición, estructura, estados electrónicos, orientación molecular, vibraciones, banda de valencia … • Otras: desorción térmica, aplicación de campos eléctricos, magnéticos. • Métodos computacionales: funcional densidad, dinámica molecular, Monte Carlo Hitos relevantes que permitieron el desarrollo experimental de la Física de superficies Ejemplos actuales de caracterización de superficies Algunas referencias • C. B. Duke: The birth and evolution of Surface science: Child of the unión of science and technology. • J Watts and J Wolstenholme: An introduction to Surface Analysis by XPS and AES. • D. Phil Woodruff Modern Techniques of Surface Science. • Surface Science Techniques, Bracco, Gianangelo • Fundamentals of Surface and Thin Film Analysis, L.C. Feldman, J.W. Mayer • Fundamental of vacuum technology, Leybold Interacción de la radiación con la materia Electrones Fotones Iones Definitions for electron transport in materials IMFP (λ) – Inelastic Mean Free Path. The average distance that an electron with a given energy travels between successive inelastic collisions. ED – Mean Escape Depth. The average depth normal to the surface from which the photoelectrons escape. AT – Attenuation Length. The quantity l in the expression x/l for the fraction of a parallel beam of X-rays or electrons that are removed by passing through a thin layer x of a substance in the limit as x approaches zero (x is in the direction of the beam). ID – Information Depth. The maximum depth, normal to the surface, from which useful information is obtained. Sampling Depth = 3λ (ID where percentage of detected electrons is 95 %). Definitions adapted from ISO 18115:2001 and Powell [47]. Definiciones frecuentes asociadas al camino libre medio Ingredientes del sistema de análisis de superficies Partícula incidente Superficie preparada Partícula saliente Analizador Espectro vs energía, masa, etc Detector y Manejo de datos Sistema de vacío Fotoemisión de electrones Dependencia con el ángulo De salida Efecto del «Background» y su efecto en la sensibilidad A tener en cuenta Influencia del modo de adquisición Modo normal y derivado Modo retardo constante y modo energía de paso constante Preparación de muestras https://www.surfacesciencewestern.com/ Sample Preparation and Processing Proper sample preparation is a key component to obtaining reliable results from our suite of advanced instrumentation. As such, SSW’s facilities include a wide variety of sample preparation, surface modification and processing equipment as well as a number of specialized sample treatment facilities. Capabilities Include: •Sample sectioning using various dry and wet cutting tools •Precision sectioning using diamond saw •Metallographic mounting and polishing in cold epoxy or bakelite medium, conductive and non- conductive mounts •Etching of polished cross-sections using suitable etchants •Freeze fracture capability •UV/Ozone surface cleaning •Ultrasonic (wet) cleaning •Basic wet chemistry facilities •Basic glove box facilities •High temperature (1250 C) heat treating capability •Heat treating under various inert gases including hydrogen, argon and nitrogen •Dosing with water vapour at controlled pressure during heat treatment •Many of our surface analytical instruments are equipped with in-situ heating (up to 600 C) or cooling to liquid nitrogen temperatures Tradicional: limpieza por sputtering de Ar entre 0.5 y 5 KeV + recocido In situ Conceptos básicos de vacío - Superficies se preparan in situ. - UHV (10-9 – 10-11 Torr) necesario para evitar contaminación P (Torr) Z1 (mol/cm 2 s) tML (s) 760 2.88x1023 2.9x10-8 10-6 3.78x1014 2.2 10-9 3.78x1011 2200 MT P Z 221 10x513.3Impactos en la superficie / cm 2 s Composición del Aire y del Gas Residual en un Sistema de Vacío Una tabla interesante relacionando varios conceptos de vacío Parámetros relevantes para otros gases Ejemplos de equipos de Análisis de Superficies «Todo Accesible» Ejemplos de equipos de Análisis de Superficies TOF-SIMS – Bariloche Todo controlado desde PC Fundamental of vacuum technology, Leybold Esquema de Vacío Mínimo para UHV Bomba para vacío preliminar: Rotativa, scroll, diafragma Bomba de UHV: Turbomolecular, Difusora, Iónica, criogénica Bombas rotatorias de paletas (Mecánicas) 1- estator 2- rotor 3- visor del nivel de aceite 4- entrada al estator 5- anti suck-valve 6- filtro 7- brida de entrada 8- brida de salida 9- trampa de aceite 10- válvula de salida 11- gas ballast 12- entrada de aceite 13- paletas Consiste en un cilindro refrigerado por agua que tiene en su interior una serie de toberas anulares que expulsan aceite a velocidades supersónicas. Este aceite es calentado por un calefactor en la parte inferior de la bomba donde se produce vapor que se expande dentro de las torres y es expulsado por las toberas formando un «paragua» de moléculas de aceite que se mueven más rápido que las moléculas del gas. Estas moléculas cuando chocan con el gas las dirige hacia abajo, hacia las siguientes etapas de bombeo generando una relación de compresión muy alta. Las moléculas de aceite deben ser condensadas en la superficie fría de la bomba para drenar hacia el calefactor y comenzar de nuevo el ciclo. Para que la bomba funcione requiere que el gas esté en el régimen molecular. Requiere pre- vacío preliminar y refrigeración de las paredes. Bombas difusoras Bombas iónicas Consiste en un conjunto de dos o tres electrodos, uno de los cuales se pone a alta tensión (3-7 KV). El fuerte campo eléctrico generado en la bomba aceleralos electrones que se encuentran en el ambiente ionizando el gas residual. Estos iones sienten el campo eléctrico y son acelerados en la dirección contraria contra los cátodos hechos de Ti. Estos átomos quedan implantados o reaccionan con el Ti, y además remueven por el impacto, átomos de Ti que son depositados en el ánodo de inoxidable. Este Ti fresco depositado en la superficie del ánodo, sirve como bomba de adsorción. Para aumentar la probabilidad de que un electrón ionice varios átomos de gas, se aplica un campo magnético transversal a la bomba para aumentar la longitud de su trayectoria. Cámaras de Vacío STM/LEED Bariloche RBS / PIXE Bariloche Cámaras de Vacío XPS/UPS/AES Bariloche Acelerador Kevatrito y cámaras de vacío TOF/ISS, LEED, UPS, EELS, AES, GIFAD Bariloche Cámaras de Vacío TOF SIMS Bariloche
Compartir