EFFECTS OF APRIL 2000 REVISION OF API 14.3 PART 2 ORIFICE METER TUBES CHANGES TO API 14.3 - APRIL 2000CHANGES TO API 14.3 - APRIL 2000 INTERNAL SURFACE FINISH UPSTREAM LENGTH STRAIGHTENING VANES FLOW CONDITIONERS 8” PLATE THICKNESS THERMOWELL LOCATION STAGGERED TAPS P LEAD LINES INCREASED DIFFERENTIAL GRANDFATHER CLAUSE INTERNAL FINISHINTERNAL FINISH WAS 250 MICROINCH THROUGHOUT CHANGES TO API 14.3 - APRIL 2000 •NOW SIZE AND BETA DEPENDENT METER TUBES TO 12” SIZE CHANGES TO API 14.3 - APRIL 2000 INTERNAL SURFACE FINISH METER TUBES 16” & LARGER INTERNAL SURFACE FINISH CHANGES TO API 14.3 - APRIL 2000 THOUGH UNDESIRABLE, ARE NOW ALLOWED, IF THEY DON’T →EXCEED I.D. TOLERANCE →EXCEED FINISH REQUIREMENT PITS CHANGES TO API 14.3 - APRIL 2000 UPSTREAM LENGTH SELECTION UPSTREAM LENGTH SELECTION →BARE TUBE ( no vane or conditioner) →SHORT TUBE WITH VANE →LONG TUBE WITH VANE →TUBE WITH CONDITIONER 4 CATEGORIES CATEGORY ( no vane or conditioner ) NOW IS 145D UNIVERSAL “CATCH ALL” METER TUBE CATEGORY Bare Meter Tubes continued, Shorter Lengths Possible For Specific Installations CATEGORY Bare Meter Tubes continued, Shorter Lengths Possible For Specific Installations →Single 90º Elbow @ .75β ---44D →(2) 90’s Out of Plane (close coupled) @ .5β --95D →Concentric Reducer @ .75β --13D →Tee (used as an elbow-not header) @ .75β --44D See detail CATEGORY NO VANE OR CONDITIONER MAX .46 BETA CATEGORY SHORT VERSION WITH VANE UNIVERSAL METER TUBE WITH VANE SHORT UPSTREAM LENGTH WITH TUBE BUNDLE COMPARISON OF OLD AND NEW REQUIREMENTS CATEGORY CATEGORY Short upstream with tube bundle CAREGORY LONG VERSION WITH VANE MAX .67 BETA UNIVERSAL METER TUBE WITH VANE CATEGORY LONG UPSTREAM WITH TUBE BUNDLE LONG UPSTREAM LENGTH WITH TUBE BUNDLE COMPARISON OF OLD AND NEW REQUIREMENTS CATEGORY THE METER TUBE LENGTH INFORMATION CONTAINED IN THIS REVISION WAS BASED ON THE RESULTS OF ACTUAL FLOW TESTING AT 12 LABS (DOMESTIC AND INTERNATIONAL), USING BOTH LIQUID AND GAS. CHANGES TO API 14.3 - APRIL 2000 CHANGES TO API 14.3 - APRIL 2000 TUBE BUNDLE STRAIGHTENING VANES 19 CONCENTRIC SAME SIZE TUBES NEW, TIGHTER TOLERANCES TUBE BUNDLE STRAIGHTENING VANES CHANGES TO API 14.3 - APRIL 2000 CONCENTRIC PATTERN HEX PATTERN NOT ALLOWED TUBE BUNDLE STRAIGHTENING VANES HEX PATTERN CHANGES TO API 14.3 - APRIL 2000 END BANDS NOT ALLOWED TUBE BUNDLE STRAIGHTENING VANES CHANGES TO API 14.3 - APRIL 2000 END BANDS 7 TUBE BUNDLE NOT ALLOWED TUBE BUNDLE STRAIGHTENING VANES CHANGES TO API 14.3 - APRIL 2000 7 TUBE BUNDLE FOR 2” SIZE FLOW CONDITIONINGFLOW CONDITIONING FLOW CONDITIONERS REMOVE SWIRL AND CREATE A NEAR FULLY DEVELOPED FLOW PROFILE CHANGES TO API 14.3 - APRIL 2000 THE DANIEL PROFILERTM CONDITIONER PLATE Profiler™ Installation METER TUBE WITH PROFILER CHANGES TO API 14.3 - APRIL 2000 Meter tube upstream lengths and beta ratio limits for use with all flow conditioners other than the standard tube bundle will be established by the manufacturer based on required testing (ref. Par. 2.5.5.4 AGA-3/API 14.3 April 2000) CHANGES TO API 14.3 - APRIL 2000 THE USE OF FLOW CONDITIONERS MAY ALLOW SHORTER UPSTREAM PIPE LENGTHS BUT A SERIES OF TESTS MUST BE RUN BEFORE OFFERING THE DEVICE TO THE MARKET CHANGES TO API 14.3 - APRIL 2000 Disturbance TestsDisturbance Tests →Good Flow Conditions →Two 900 Elbows in Perpendicular Planes →Gate Valve 50% Closed →High Swirl CHANGES TO API 14.3 - APRIL 2000 Flow Conditioner Qualification Test CHANGES TO API 14.3 - APRIL 2000 Flow Conditioner Qualification Test •Good Flow Conditions - test evaluating impact of flow conditioner on fully developed velocity profile. •Install the conditioner in the specified location preceding a meter tube where the installation has been shown to already have a swirl free, fully developed profile. This proves the device has no negative effect on flow. •Two 900 Elbows in Perpendicular Planes - testing of flow conditioner performance in handling combination of a modest swirl and a non-symmetrical velocity profile. CHANGES TO API 14.3 - APRIL 2000 Flow Conditioner Qualification Test Gate Valve 50% Closed - test evaluating flow conditioner performance in strongly non-symmetrical velocity profile CHANGES TO API 14.3 - APRIL 2000 Flow Conditioner Qualification Test •High Swirl - test assessing flow conditioner performance in flows with high swirl angle (over 250). CHANGES TO API 14.3 - APRIL 2000 Flow Conditioner Qualification Test Swirl must be reduced to 2º Max Additional TestsAdditional Tests – Orifice β ratio: Check swirl test at β=0.40 and β=0.67 – Reynolds Number Sensitivity: Test at two ranges 10,000 < Re <500,000 and Re > 1MM with approximately a 7:1 ratio. – Scaling: Test at two sizes selected from D < 4” and D > 8” Flow Conditioner Qualification Test CHANGES TO API 14.3 - APRIL 2000 ANY FLOW CONDITIONER CHOSEN SHOULD HAVE TEST DATA SHOWING COMPLIANCE WITH THE TESTING PROGRAM OUTLINED IN AGA/14.3 CHANGES TO API 14.3 - APRIL 2000 CHANGES TO API 14.3 - APRIL 2000CHANGES TO API 14.3 - APRIL 2000 WAS 12” TO 36” UPSTREAM OF VANE NOW IS 36” MINIMUM UPSTREAM OF VANE UPSTREAM THERMOWELL LOCATION STAGGERED PRESSURE TAPSSTAGGERED PRESSURE TAPS NOT ALLOWED CHANGES TO API 14.3 - APRIL 2000 STAGGERED PRESSURE TAPS PLATE THICKNESS CHANGE →8” SIZE WAS 1/8” THICK →NOW IS 1/4” THICK CHANGES TO API 14.3 - APRIL 2000 Reason: differential was limited to 150” in an orifice fitting →Some 1/8” and 1/4” seal/plate assemblies may be interchangeable in the same fitting, allowing installation of the wrong plate in the right fitting CHANGES TO API 14.3 - APRIL 2000 IMPACT OF 8” PLATE CHANGE TO 1/4” THICK →Plate carriers and/or seal rings for some manufacturers’ fittings may be different for 1/8” and 1/4” thick plates CHANGES TO API 14.3 - APRIL 2000 IMPACT OF 8” PLATE CHANGE TO 1/4” THICK →Existing installations using 1/8” thick plates will require careful organization if 1/4” units are added IMPACT OF 8” PLATE CHANGE TO 1/4” THICK CHANGES TO API 14.3 - APRIL 2000 PLATE THICKNESS CHANGE →24” SIZE WAS 3/8” THICK →NOW IS 1/2” THICK CHANGES TO API 14.3 - APRIL 2000 Reason: differential was limited to 150” DP TAP CONNECTION LINE LENGTHS CHANGES TO API 14.3 - APRIL 2000 →EQUAL LENGTH LINES →SHORT AS POSSIBLE DP TAP CONNECTION LINE LENGTHS CHANGES TO API 14.3 - APRIL 2000 DIFFERENTIAL TAP LINE LENGTHDIFFERENTIAL TAP LINE LENGTH IF RESONANCE OR PULSATION IS SUSPECTED, – CALCULATE PROPER LENGTH USING THESE 5 EQUATIONS BASED ON PULSATION FREQUENCY (f) AND SPEED OF SOUND IN FLUID (a) length L = factor x a / (2 B f ) 0.25 2.5 5.5 8.5 11.5 THE RESULTING LENGTH NEAREST THAT PREFERRED SHOULD BE USED CHANGES TO API 14.3 - APRIL 2000 DP TAP CONNECTION LINE LENGTHS INCREASED DIFFERENTIAL PRESSUREINCREASED DIFFERENTIAL PRESSURE TABLES SHOWING MAXIMUM DP FOR RECOMMENDED PLATE THICKNESSES – 304SS AND 316SS – TEMPERATURES TO 150ºF (65ºC) – INSTALLED IN BOTH FITTINGS AND FLANGES • FLANGES ALLOW MUCH HIGHER DIFFERENTIALS CHANGES TO API 14.3 - APRIL 2000 INCREASED DIFFERENTIAL PRESSURES INCREASED DIFFERENTIAL PRESSURE CONTINUED INCREASED DIFFERENTIAL PRESSURE CONTINUED SOME SIZES ALLOW UP TO 1000” DP – VALUES BASED ON PLATE DEFLECTION ONLY – ANY OPERATIONAL EFFECTS ON ORIFICE FITTINGS NOT CONSIDERED ADDITIONAL TABLES FOR OTHER THAN STANDARD PLATE THICKNESSES IN APPENDIX CHANGES TO API 14.3 - APRIL 2000 INCREASED DIFFERENTIAL PRESSURES CHANGES TO API 14.3 - APRIL 2000CHANGES TO API 14.3 - APRIL 2000 POSSIBLE EFFECT OF DIFFERENTIAL PRESSURES EXCEEDING VALUES SHOWN INCREASED DIFFERENTIAL PRESSURES GRANDFATHER CLAUSE From API 14.3 Part 2, Par 2.1, April 2000 CHANGES TO API 14.3 - APRIL 2000 It is strongly recommended that a copy of the new standard be obtained and read thoroughlyas there are many details not covered in this presentation It is strongly recommended that a copy of the new standard be obtained and read thoroughly as there are many details not covered in this presentation CHANGES TO API 14.3 - APRIL 2000 THE ENDTHE END CHANGES TO API 14.3 - APRIL 2000 TAP HOLE LOCATION TOLERANCE FROM 14.3 HOW TO MEET 14.3 WITH A 1/4” THICK PLATE IN A FITTING DRILLED FOR A 1/8” THICK PLATE 4” & LARGER LIMIT BETA TO .6 If distance “S” between 2 fittings is 22D or more, only the fitting nearest the orifice is considered 2.6.3.1 CHANGES TO API 14.3 - APRIL 2000 CHANGES TO API 14.3 - APRIL 2000 INTERNAL FINISH CATEGORYBare Meter Tubes continued,Shorter Lengths Possible For Specific Installations FLOW CONDITIONING Disturbance Tests Additional Tests CHANGES TO API 14.3 - APRIL 2000 STAGGERED PRESSURE TAPS DIFFERENTIAL TAP LINE LENGTH INCREASED DIFFERENTIAL PRESSURE INCREASED DIFFERENTIAL PRESSURECONTINUED CHANGES TO API 14.3 - APRIL 2000 It is strongly recommended that a copy of the new standard be obtained and read thoroughly as there are many details not cover THE END
Compartir